Care and Cleaning
Cleaning
Use a vacuum cleaner to remove light dust. If there is
sticky dust on the filter, wash the filter in lukewarm,
soapy water, rinse it in clean water, and dry it.
How to replace the anti-mold filter
Insert the top of the anti-mold filter,
and then fit the protursions
on the bottom of the filter
all the way into the hooks
on the unit.
Press the locations
marked by the arrows
and close the front panel.
Anti-mold filter
Air Clean Filter
The air clean filter removes dust and dirt from
the air, and reduces odors andsmoke from tobacco.
WARNING
This air clean filter cannot remove harmful gases
or vapors nor ventilateair in the room. You must
open doors or windows frequently when you use
gas or oil heating appliances. Otherwise there is
a risk of suffocation in extreme cases.
How to install the air clean filter
The air clean filter needs to
be installed behind
the anti-mold filter.
Open the frontpanel
and remove the
anti-mold fitlers,
then install the air clean filter
in the position shown in thefigure.
After that, remount the anti-mold filters
and close the front panel.
NOTE
• Do not bend nor give excessive force onto the air
the air clean filter.
• If the filter surface is heavily blocked with dirt or
damaged, replace it with new one.
Purchase a replacement filter at your local dealer.
(model: STK-FWWB)
(continued)
Front Panel
Air clean filter
Cleaning the main unit and remote control unit
• Wipe clean using a soft, dry cloth.
• To remove stubborn dirt, moisten a cloth in warm water
no hotter than 40 °C, wring thoroughly, and then wipe.
• The air intake grille can be removed in order to wash it
with water.
Removing and remounting the front panel
1. Open the front panel until it is nearly horizontal,
grasp the sections near the front panel arms on
remove the panel by pushing the arms towards the
outside both sides, and then while pulling the panel
towards you.
Front panel
2. Grasp the sections near the front panel arms on both
sides, and hold the front panel so that it is nearly
horizontal. Push the arm shafts towards the outside
so that they come into contact with the top of the
indentations on the right and left sides of the air
conditioner. Then push firmly until the arm shafts
click into place. After closing the front panel,
press firmly on the parts indicated by the arrows to
securely fasten the panel in place.
Also refer to the figure that shows "How to replace
the anti-mold filter".
When using a footstool or
CAUTION
the like, be careful not to
let it tip over.
Washing the front panel with water
• Clean the grille gently using a soft sponge,
or the like. Then wipe away any remaining
moisture.
• Neutral detergent may be used to remove
stubborn dirt. Then rinse thoroughly with water
and wipe away any remaining moisture.