Sanyo SAP-K77GHAX Technical & Service Manual page 116

Table of Contents

Advertisement

Indoor Unit
SAP-K127GHAX
Outdoor Unit SAP-C127GHAX
Cooling
Performance at
Rating Conditions
Full Load Conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Full Load conditions: Indoor air temperature:
Outdoor air temperature:
Heating
Performance at
Rating Conditions
Full Load Conditions
Rating conditions:
Indoor air temperature:
Outdoor air temperature:
Full Load conditions: Indoor air temperature:
Outdoor air temperature:
Running Amps.
A
Power Input
kW
Running Amps.
A
Power Input
kW
27 C D.B. / 19 C W.B.
35 C D.B.
32 C D.B. / 23 C W.B.
43 C D.B.
Running Amps.
A
Power Input
kW
Running Amps.
A
Power Input
kW
20 C D.B.
7 C D.B. / 6 C W.B.
27 C D.B.
24 C D.B. / 18 C W.B.
Indoor Unit
Fan Motor
Fan Motor
220/230/240V Single phase 50Hz
0.19
0.39
0.031
0.090
0.19
0.39
0.031
0.090
Indoor Unit
Fan Motor
Fan Motor
220/230/240V Single phase 50Hz
0.19
0.39
0.031
0.090
0.19
0.39
0.031
0.090
33
Outdoor Unit
Compressor
5.62
1.184
7.19
1.555
Outdoor Unit
Compressor
5.32
1.154
7.19
1.555
Complete Unit
6.2
1.305
7.77
1.676
Complete Unit
5.9
1.275
7.77
1.676

Hide quick links: