Outdoor Unit
SAP-C97GHAX
Controller PCB
Compressor
Type
Compressor model / Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25 C)
Safety devices Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25 C)
Run capacitor
Crankcase Heater
Fan
Type
Q'ty ... Dia.
Fan Motor
Type
Fan motor model ... Q'ty
No. of poles
Rough Measure RPM (Cool/Heat)
Nominal output
Coil resistance (Ambient temp. 20 C)
Safety devices Type
Operating temp.
Run capacitor
Heat Exchanger Coil
Coil
Rows
Fin pitch
Face area
External Finish
CC
Ohm
Open
C
Close
C
Micro F
VAC
mm
W
Ohm
Open
C
Close
C
Micro F
VAC
mm
2
m
13
Single Rotary
C-1R81H5T / 800W
SAY-56T ...320
C - R : 4.27
C - S : 4.56
External ( OLR )
MRA99248-9201
155 5
69 11
Trip in 6 to 16 sec. at 17.0A
30.0
370
-
Propeller
1 ... D380
AC Motor
IB-976-501D ... 1
6
820 / 820
25
BRN - WHT : 213.4 10%
RED(PNK) - WHT : 167.7 10%
Thermal protector
110
-
2.0
440
Aluminum Plate Fin / Copper Tube
1
1.2
0.341
Acrylic baked-on enamel finish