Siemens SITRANS F US Operating Instructions Manual page 45

Ultrasonic flowmeter for use with sensor type sono 3100, sono 3300 and sonokit 1- and 2-tracks
Hide thumbs Also See for SITRANS F US:
Table of Contents

Advertisement

Roughness, menu 7.1.3.2 (to be changed for SONOKIT only)
Roughness is the value for the surface inside the pipe.
The range of this value is defined to 0.01 mm to 10.0 mm because standard Siemens sensors
have a roughness of approximately 0.4 mm.
Smooth plastic pipe
Polished stainless steel pipe
Standard carbon steel pipe
Rusty carbon steel pipe
Concrete pipe
Tracks, menu 7.1.4 (to be changed for SONOKIT only)
This menu is for the parameters which are for the track settings. In the following table only the
parameters for track 1 are explained.
The parameters for tracks 2, 3, and 4 are to be handled like track 1.
Note
The menus 7.1.4.1.x.x and 7.2 are not for flowmeter systems with sensors
SONO 3100 and SONO 3300. Please do not change these values. They are determined
and preset at the factory.
Track 1, menu 7.1.4.1.1 and menu 7.1.4.2.1 (to be changed for SONOKIT only)
For SONOKIT: Data to be entered from "SENSOR GEOMETRY MEASUREMENT REPORT"
Length 1
7.1.4.1.1 Length 1
The length of the first track
This parameter is the distance between the ultrasonic transducers, as illustrated in the picture.
The value is necessary in order to calculate the ultrasonic velocity from the time of flight and
the distance between the transducers.
Angle 1, menu 7.1.4.1.2 and menu 7.1.4.2.2 (to be changed for SONOKIT only)
Angle of track 1.
It is not necessary to enter this menu is not necessary for flowmeter systems with sensors SONO
3100 and SONO 3300. These values are determined and preset at the factory.
For SONOKIT: Data to be entered from "SENSOR GEOMETRY MEASUREMENT REPORT"
SFIDK.PS.029.E5.02 / SW 2.01.07
0.1 mm
0.1 mm
0.4 mm
1...2 mm
2...5 mm
0.2 m
>0 m ... 8.0 m
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fus060 hart

Table of Contents