Siemens SITRANS F US Operating Instructions Manual page 2

Ultrasonic flowmeter for use with sensor type sono 3100, sono 3300 and sonokit 1- and 2-tracks
Hide thumbs Also See for SITRANS F US:
Table of Contents

Advertisement

This operating manual is for the transmitter part of the flowmeter consisting of sensors type SONO 3100,
System overview
SONO 3300 and SONOKIT. These sensors have separate operating manuals.
SITRANS F US
FUS060 with
Sensor
SONO 3100,
SONOKIT
and SONO 3300
Size [ [ [ [ [ mm] ] ] ] ]
Connection
examples
Pressure [ [ [ [ [ bar] ] ] ] ]
Media temperature
Max. °C ( ( ( ( ( °F) ) ) ) )
Transducer
Enclosure
Approvals
Transmitter
Enclosure
Mounting
Accuracy
Materials
Outputs
Display/counter
Language
Approval
Supply voltage
2
Mild steel
Standard program
SONO 3300
DN 50 - DN 300
PN 10, PN 16,
Class 150, Class 300
160 (320)
Integrated transducers
SFIDK.PS.029.E5.02 / SW 2.01.07
Stainless steel
and mild steel
Extended program
SONO 3100
DN 100 - DN 1200
EN 1092-1
ANSI B 16.5 150 lbs RF
ANSI B 16.5 300 lbs RF
PN 10, PN 16,
PN 40,
PN 25, PN 40
Class 150, Class 300
200 (394)
SONO 3200
O-ring type
Flange type
IP67
ATEX
IP65 (NEMA 4)
Separate wall mounting
± 0.5% of actual flow
Die-cast aluminium
1 current / HART / Profibus PA
1 frequency/pulse
Alphanumeric: flow, quantity,
error, mass flow, sound velocity, etc.
English, German, French, Spanish
115/230 V AC
24 V AC/DC
Retrofit program
1 or 2-tracks
SONOKIT
DN 100 - DN 4000
Max. PN 40
200 (394)
SONO 3200
O-ring type
IP68
ATEX
FUS060
1 relay
ATEX
None
IP68
ATEX

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fus060 hart