This operating manual is for the transmitter part of the flowmeter consisting of sensors type SONO 3100,
System overview
SONO 3300 and SONOKIT. These sensors have separate operating manuals.
SITRANS F US
FUS060 with
Sensor
SONO 3100,
SONOKIT
and SONO 3300
Size [ [ [ [ [ mm] ] ] ] ]
Connection
examples
Pressure [ [ [ [ [ bar] ] ] ] ]
Media temperature
Max. °C ( ( ( ( ( °F) ) ) ) )
Transducer
Enclosure
Approvals
Transmitter
Enclosure
Mounting
Accuracy
Materials
Outputs
Display/counter
Language
Approval
Supply voltage
2
Mild steel
Standard program
SONO 3300
DN 50 - DN 300
PN 10, PN 16,
Class 150, Class 300
160 (320)
Integrated transducers
SFIDK.PS.029.E5.02 / SW 2.01.07
Stainless steel
and mild steel
Extended program
SONO 3100
DN 100 - DN 1200
EN 1092-1
ANSI B 16.5 150 lbs RF
ANSI B 16.5 300 lbs RF
PN 10, PN 16,
PN 40,
PN 25, PN 40
Class 150, Class 300
200 (394)
SONO 3200
O-ring type
Flange type
IP67
ATEX
IP65 (NEMA 4)
Separate wall mounting
± 0.5% of actual flow
Die-cast aluminium
1 current / HART / Profibus PA
1 frequency/pulse
Alphanumeric: flow, quantity,
error, mass flow, sound velocity, etc.
English, German, French, Spanish
115/230 V AC
24 V AC/DC
Retrofit program
1 or 2-tracks
SONOKIT
DN 100 - DN 4000
Max. PN 40
200 (394)
SONO 3200
O-ring type
IP68
ATEX
FUS060
1 relay
ATEX
None
IP68
ATEX