Step 2 - Select Location; Ii. Step 2 — Select Location - Bryant 619CNF Installation, Start-Up And Service Instructions Manual

Ceiling-suspended fan coil units
Table of Contents

Advertisement

UNIT SIZE
NOMINAL CAPACITY (tons)
NOMINAL SIZE (Btuh)
OPERATING WEIGHT (lb)
MOISTURE REMOVAL WEIGHT
(Pints/Hr)
FINISH
REFRIGERANT
Control (Cooling)
INDOOR FAN
Rpm...Cfm High
Rpm...Cfm Medium
Rpm...Cfm Low
High Speed Watts
Motor Quantity
Blowers — No. ...Size (in.)
INDOOR COIL
Face Area (sq ft)
No. of Rows
Fins/in.
Circuits
FILTERS
Quantity
HEATERS (kW)
AIRSWEEP
Horizontal
Vertical
CONTROLS
Control Voltage
Defrost Method
Dehumidification
Auto Restart
Fan Speed
Condensate Pump Safety
Filter Change Indication
Freeze Protection
REFRIGERANT LINES
Connection Type
Liquid Line OD (in.)
Vapor Line OD (in.)
Max Line Length
CONDENSATE DRAIN
CONNECTION
CONDENSATE DRAIN SIZE (in.)
*Field reconfigured to 18,000 Btuh (1
section on page 3 for details.
3. Remove inlet grilles from indoor unit by sliding for-
ward. Reinstall prior to unit start-up.
IMPORTANT: If necessary, reconfigure the 24,000 Btuh fan coil
unit to 18,000 Btuh. Unplug the fan motor at the control box
harness and plug into the 619CN018 marked connector.
II. STEP 2 — SELECT LOCATION
Consult local building codes and NEC for special installation
requirements. See Fig. 3 and 4 for unit dimensions and
required clearances.
There are several ways the unit may be installed to different
types of ceiling construction. These instructions do not cover
all installation methods. As a typical installation, these
instructions focus primarily on mounting the unit to metal in
Table 3B — Physical Data, Under Ceiling Heat Pump Units
018*
024
1
1
/
2
2
18,000
24,000
110
110
4.0
7.3
900...480
1050...550
862...400
900...480
770...320
862...400
92
92
1
1
2...6x8
2...6x8
2.2
2.2
4
4
14.9
14.9
4
4
4
4
2.0
2.0
5
5
/
/
8
8
For maximum line lengths see condensing unit instructions.
1
/
tons). See Before Installation
2
030
036
3
30,000
36,000
119
119
6.0
9.0
GM Motorhome White with Black Trim
R-410A
AccuRater Control
Direct Drive Centrifugal
1275...840
1275...840
972...740
972...740
830...640
830...640
282
282
1
2...6x8
2...6x8
Copper Tube, Aluminum Fin
2.6
2.6
4
14.9
14.9
4
Cleanable
5
3.0
3.0
User select ON/OFF
Manual
24 V
Timed
Yes
Yes
High/Medium/Low
Yes (Accessory)
250 Hours of Indoor Fan Operation
Indoor coil less than 28 F, resets at 50 F.
Flare
3
/
8
3
/
4
Pipe Thread (MPT)
3
/
4
†The valve connection size is
1
1
/
inch.
8
new construction. Plan the installation carefully before you
begin. Listed below are some guidelines that should be fol-
lowed when determining location for the unit.
1. Place unit adjacent to an outside wall if fresh air is
required, ensuring that location allows for complete
air distribution.
2. Locate the thermostat in an area that is not subjected
to drafts or direct sunlight through windows. Locate
the thermostat on an internal wall whenever possible.
3. Allow sufficient clearance for airflow, wiring, refriger-
ant piping, and servicing unit (Fig. 3 and 4).
4. Make sure the unit is easily accessible to electrical
power.
—4—
048
3
4
48,000
151
13.0
1435...1130
1388... 975
1315... 820
425
1
2
3...6x8
3.0
4
4
14.9
4
8
5
6
4.0
3
7
/
/
4
8
7
/
inch. The recommended line size is
8
060
5
60,000
181
14.5
TXV
1275...1600
972...1220
830...1040
564
2
4...6x8
4.0
4
14.9
8
8
5.0
7
/
8