Sign In
Upload
Manuals
Brands
Bryant Manuals
Air Conditioner
551J Series
Bryant 551J Series Manuals
Manuals and User Guides for Bryant 551J Series. We have
4
Bryant 551J Series manuals available for free PDF download: Installation, Start-Up And Service Instructions Manual, Installation Instructions Manual
Bryant 551J Series Installation Instructions Manual (56 pages)
SINGLE PACKAGE ROOFTOP COOLING ONLY SIZES 07, 08, 09, 11 AND 12 WITH PURONR (R--410A) REFRIGERANT
Brand:
Bryant
| Category:
Heat Pump
| Size: 5.3 MB
Table of Contents
Table of Contents
1
Theinstallation.
2
Safety Considerations
2
Rated Indoor Airflow (Cfm)
3
Installation
8
Jobsite Survey
8
Step 1 - Plan for Unit Location
8
Roof Mount
8
Step 2 - Plan for Sequence of Unit Installation
8
Curb- - Mounted Installation
9
Pad- - Mounted Installation
9
Frame- - Mounted Installation
9
Step 3 - Inspect Unit
9
Step 4 - Provide Unit Support
9
Roof Curb Mount
9
Slab Mount (Horizontal Units Only)
9
Alternate Unit Support (in Lieu of Curb or Slab Mount)
11
Step 5 - Field Fabricate Ductwork
11
For Units with Accessory Electric Heaters
11
Step 6 - Rig and Place Unit
11
Positioning on Curb
12
Step 7 - Convert to Horizontal and Connect
12
Ductwork
12
Step 8 - Install Outside Air Hood
13
Economizer and Two Position Damper Hood Package Removal and Setup - Factory Option
13
Economizer Hood and Two- - Position Hood
13
Step 9 - Install External Condensate Trap and Line
14
Step 10 - Make Electrical Connections
14
Field Power Supply
14
Units with Factory- - Installed Non- - Fused Disconnect
15
Non- - Fused Disconnect
15
Units Without Factory- - Installed
16
Non- - Fused Disconnect
16
All Units
16
Convenience Outlets
17
Factory Option Thru- - Base Connections
18
Units Without Thru- - Base Connections
18
Field Control Wiring
18
Thermostat
18
Central Terminal Board
19
Unit Without Thru- - Base Connection Kit
19
Heat Anticipator Settings
19
Electric Heaters
19
Single Point Boxes and Supplementary Fuses
20
Single Point Boxes Without Fuses
20
Low- - Voltage Control Connections
21
Low Ambient Control (Factory Option)
21
Variable Frequency Drive (VFD) 2- - Speed Indoor Fan Motor System (Factory- - Installed)
21
Perfect Humidityt System Control Connections
21
Perfect Humidity System - - Space RH Controller
21
Economi$Er R X (Factory- -Installed Option)
23
Product Description
23
System Components
23
Specifications
23
W7220 Economizer Module
23
Electrical
23
Inputs
23
Outputs
24
Environmental
24
Economizer Module Wiring Details
24
S- - Bus Sensor Wiring
24
CO 2 Sensor Wiring
25
Interface Overview
25
User Interface
25
Keypad
25
Menu Structure
26
Setup and Configuration
26
Time- - out and Screensaver
26
Sequence of Operation
32
Enthalpy Settings
35
Two- -Speed Fan Operation
35
Checkout
36
Power up
36
Initial Menu Display
36
Power Loss (Outage or Brownout)
37
Status
37
Checkout Tests
37
Troubleshooting
37
Alarms
37
RTU Open Controller System
38
Supply Air Temperature (SAT) Sensor
41
Outdoor Air Temperature (OAT) Sensor
41
Economi$Er R 2
42
Field Connections
42
Space Temperature (SPT) Sensors
42
Indoor Air Quality (CO 2) Sensor
43
Outdoor Air Quality Sensor
43
Space Humidity Sensor or Humidistat
44
Smoke Detector/Fire Shutdown (FSD)
45
Connecting Discrete Inputs
45
Communication Wiring - - Protocols
46
General
46
Local Access
47
RTU Open Controller Troubleshooting
47
Outdoor Air Enthalpy Control
48
Differential Enthalpy Control
48
Return Air Enthalpy Sensor
48
Smoke Detectors
49
Step 11 - Adjust Factory- -Installed Options
50
Step 12 - Install Accessories
50
Step 13 - Check Belt Tension
51
Start- - up Checklist
55
Advertisement
Bryant 551J Series Installation, Start-Up And Service Instructions Manual (64 pages)
Variable Frequency Drive (VFD) Factory-Installed Option 2-Speed Motor Control for 2-Stage Cooling Rooftop Units
Brand:
Bryant
| Category:
Air Conditioner
| Size: 12.82 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
2-Speed Indoor Fan Motor Indoor Fan Speed System
2
Identifying Factory Option
2
Unit Installation with 2-Speed Indoor Fan Motor Option
2
Pre-Start Check, 2-Speed Indoor Fan Motor Option
5
Start-Up, 2-Speed Indoor
16
Fan Motor Option
16
Compressor Rotation
16
Indoor Fan Motor
16
Cooling with 2-Speed Indoor Fan Motor
16
Operating Sequences, 2-Speed Indoor Fan Motor Option
16
Cooling (FAN Switch in AUTO)
16
Heating
17
Operating Fan for Test and Balance
17
Service
18
2-Speed Indoor Fan Motor Option Components
18
Fan Speed Relay Board
18
Configuration Jumpers
18
Variable Frequency Drive
18
Central Terminal Board Jumpers (548J/549J/551J/558J/580J/581J Series Only)
20
VFD Fuses
21
Control and Power Wiring Diagrams
22
Vfd Alarms and Faults Troubleshooting
29
Alarms
29
Faults
29
Vfd Maintenance
30
Heat Sink Cleaning
30
Fan Replacement
31
Bypass the VFD
33
Vfd Parameters
34
Vfd Remote Keypad
45
ACH550/ACS320 Operation with Remote Keypad
45
ACH550/ACS320 VFD Modes
45
ACH550/ACS320 VFD Diagnostics
47
Correcting Faults
47
History
47
Reset after Using Start-Up Assistant
50
ACH580 Operation with Remote Keypad
51
ACH580 VFD Modes
52
ACH580 VFD Diagnostics
54
All Ach580, Ach550 and Acs320 Keypads
57
Control Panel Cleaning
57
Battery Replacement
57
VFD Remote Keypad Parameters
57
Bryant 551J Series Installation Instructions Manual (24 pages)
3 to 12.5 Tons (48/50LC 14 Not Included) Accessory Ultra Low Leak Vertical EconoMiser X
Brand:
Bryant
| Category:
Air Conditioner
| Size: 2.86 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
Accessories List
3
Compliance
3
Installation
4
Instructions for 48/50LC 07-12 Units Only
9
Installing Optional HH57AC081 Single Outside Air
13
Enthalpy Sensor
13
Installing Differential Return Air Sensor
14
California's Title 24 High Temperature Limit
14
Settings
14
Demand Controlled Ventilation (DCV)
14
Remote (Downstairs) Monitoring of Controller's Fault Detection and Diagnostics
15
General W7220 Controller and Sensor Information
16
W7220 Economizer
16
User Interface
16
Keypad
16
Using the Keypad with Menus
16
Using the Keypad with Settings and Parameters
16
Menu Structure
16
Programming W7220 Controller
16
Setpoints
16
System Setup
17
Checkout Tests
21
W7220 Economizer Module Wiring
22
Time-Out and Screen Saver
22
Start-Up and Operation
22
Cooling, Unit with Economi$Er® X
22
Heating with Economi$Er® X
22
Troubleshooting
24
Power Loss (Outage or Brownout)
24
Alarms
24
Clearing Alarms
24
Advertisement
Bryant 551J Series Installation Instructions Manual (36 pages)
SINGLE PACKAGE ROOFTOP COOLING ONLY SIZES 04-06 with PURON (R-410A) REFIRGERANT
Brand:
Bryant
| Category:
Air Conditioner
| Size: 5.53 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
Installation
5
Step 1 - Plan for Unit Location
5
Step 2 - Plan for Sequence of Unit Installation
5
Step 3 - Inspect Unit
6
Step 4 - Provide Unit Support
6
Step 5 - Field Fabricate Ductwork
8
Step 6 - - Rig and Place Unit
8
Step 7 - - Convert to Horizontal and Connect Ductwork
9
Step 8 - Install Outside Air Hood
9
Step 9 - Install External Condensate Trap and Line
11
Step 10 - - Make Electrical Connections
11
Step 11 - Adjust Factory- -Installed Options
35
Step 12 - Install Accessories
36
Advertisement
Related Products
Bryant 551B
Bryant 551C
Bryant 551K 05N Series
Bryant 551K 05R Series
Bryant 551K 06N Series
Bryant 551K 06R Series
Bryant 551B Series
Bryant 551B048
Bryant 551B060
Bryant 551B072
Bryant Categories
Furnace
Air Conditioner
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL