INSTALLATION LOCATION
REQUIREMENTS
S
A location where there are no obstacles near inlet and outlet
area.
S
A location which can bear the weight of indoor unit.
S
Do not install indoor units near a direct source of heat such
as direct sunlight or a heating appliance.
S
A location which provides appropriate clearances as
outlined in Fig. 4.

INDOOR UNIT INSTALLATION

INSTALL THE MOUNTING HOOKS
1. The mounting hooks should be located horizontally and
level on the wall. All minimum clearances shown in Fig. 4
should be maintained.
2. Anchor the hooks at the specified location on the wall using
the mounting screws (see Fig. 4). Anchor the hooks on wall
studs.
Fig. 4 - Anchor the hooks
3. Once the hooks are secured, lift the unit and mount it on
the hooks. Be sure the hooks are on the correct mounting
locations on the back of the unit. (see Fig 5.)
Fig. 5 - Hang the indoor unit
Hook
Tapping
screw
Washer
<6mm
A150704
Hook
Tapping screw
Washer
<6mm
A150705
DRILL A HOLE IN WALL FOR
INTERCONNECTING PIPING, DRAIN AND WIRING
For maximum serviceability, it is recommended that you have
refrigerant line flare connections and the drain connections on the
outside of the wall that the fan coil can be mounted on.
1. Determine the pipe hole position.
2. Drill the pipe hole. The outside pipe hole is 1/2−in. (13 mm)
lower than the inside pipe hole, so it slants slightly down-
ward (see Fig. 6).
Fig. 6 - Drill holes
INDOOR UNIT PREPARATION
1. Open the Front Panel sliding the two stoppers towards the
middle of the indoor unit (see Fig 7).
Fig. 7 - Open the Front Panel
2. Remove the front (see Fig. 8).
a. Disengage the string.
b. Remove the four screws.
Fig. 8 - Remove the screws