CAUTION: Do not install the
reference station on a flagpole.
Movements of the reference
station will affect the correction
data sent to the product with the
accurate position.
Example A shows the best installation of the
reference station. It is installed high with free
view to the sky.
Example B shows a good installation of the
reference station. It is installed at a distance
to buildings and trees and have free of view
to the sky in more than 120°.
Example C shows a bad installation of the
reference station. It is installed too near
trees and buildings with limited view to the
sky.
A
B
>120°
C
Install the reference station minimum 1.5 m /
4.9 ft. from large objects that can block the
18 - Installation
signals from the reference station.
Recommended distance is 3 m / 10 ft.
Install the reference station where the radio
signal reaches all parts of the work area.
It is recommended to have free line of sight
between product and reference station for
optimal performance.
The maximum distance between the
reference station and the product is 250 m /
820 ft. when free line of view. Objects
between the reference station and product
decreases the distance.
Install the reference station within reach of a
power outlet.
Note: The low-voltage cable is 20 m / 65 ft.
3.5 To examine where to put the
charging station
Note: Do not install a mower house that will
cause a blockage to the GPS signals.
Put the charging station in free line of view
with the reference station.
Put the charging station in an open position
with free view to the sky.
Keep a minimum 3 m / 10 ft. of free space in
front of the charging station. Refer to
examine where to install the Virtual guide on
page 22 .
Keep a minimum of 1.5 m / 5 ft. of free
space to the right and left of the center of
the charging station.
Put the charging station near a power outlet.
Put the charging station on a level surface.
The baseplate of the charging station must
not be bent.
max. 5 cm / 2"
max. 5 cm / 2"