Panasonic AK-SHB800G Operating Manual page 72

8k multi purpose camera, image processing unit
Hide thumbs Also See for AK-SHB800G:
Table of Contents

Advertisement

Item
[W V SAW G]
[W V SAW B]
[W V PARA R]
[W V PARA G]
[W V PARA B]
[BLACK SHADING]
Item
[CORRECT]
[DETECTION]
[SAVE]
[CLEAR]
[VUP TALLY]
Item
[VUP TALLY]
[FAN SETTING]
Item
[FAN_CAM MODE]
[ROP ABB]
Item
[ROP ABB]
Chapter 4 Menu Operations — Menu list (AK-SHU800)
Adjusts Gch white shading for the data selected in [FILE NO.] vertically using a saw-toothed waveform.
[−100]...[+100]
f Factory setting: [0]
Adjusts Bch white shading for the data selected in [FILE NO.] vertically using a saw-toothed waveform.
[−100]...[+100]
f Factory setting: [0]
Adjusts Rch white shading for the data selected in [FILE NO.] vertically using a parabolic waveform.
[−100]...[+100]
f Factory setting: [0]
Adjusts Gch white shading for the data selected in [FILE NO.] vertically using a parabolic waveform.
[−100]...[+100]
f Factory setting: [0]
Adjusts Bch white shading for the data selected in [FILE NO.] vertically using a parabolic waveform.
[−100]...[+100]
f Factory setting: [0]
Enables/disables the auto correction function of black shading.
[OFF], [ON]
f Factory setting: [ON]
Selects whether to execute auto correction function of black shading.
[NO], [YES]
Selects whether to save the auto correction data.
[NO], [YES]
Selects whether to clear the auto correction data.
[NO], [YES]
Sets whether to have the tally lamps on the camera head blinking while updating the firmware.
[ON]: The tally lamps on the camera head blink while updating the firmware.
[OFF]: The tally lamps on the camera head do not blink while updating the firmware.
.
f Factory setting: [ON]
Sets the operation mode of the cooling fan on the camera head.
[AUTO], [LOW]
f Factory setting: [AUTO]
@
NOTE
t Use in an environment with ambient temperature of 30 °C (86 °F) or less when using in [LOW].
Selects whether to execute AUTO BLACK from the ROP.
[ON]: Enables the ABB button of the ROP.
[OFF]: Disables the ABB button of the ROP.
f Factory setting: [OFF]
– 72 –
Description of settings
Description of settings
Description of settings
Description of settings
Description of settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ak-shb800psAk-shu800psAk-shu800e

Table of Contents