Panasonic AK-SHB800G Operating Manual page 59

8k multi purpose camera, image processing unit
Hide thumbs Also See for AK-SHB800G:
Table of Contents

Advertisement

[GAMMA/BLACK GAMMA]
Item
[GAMMA]
[MASTER GAMMA]
[R GAMMA]
[B GAMMA]
[BLACK GAMMA]
[MASTER BLACK GAMMA]
[R BLACK GAMMA]
[B BLACK GAMMA]
[KNEE]
Item
[KNEE]
[KNEE MASTER POINT] Sets the knee point position.
[KNEE R POINT]
[KNEE B POINT]
[KNEE MASTER
SLOPE]
[KNEE R SLOPE]
[KNEE B SLOPE]
Chapter 4 Menu Operations — Menu list (AK-SHU800)
Enables/disables gamma correction.
[OFF], [ON]
f Factory setting: [ON]
Adjusts the gamma characteristic.
[0.150]...[0.750] (0.0020 step)
f Factory setting: [0.450]
Adjusts the gamma characteristic of red to the master gamma.
[−75]...[+75]
f Factory setting: [0]
Adjusts the gamma characteristic of blue to the master gamma.
[−75]...[+75]
f Factory setting: [0]
Enables/disables black gamma.
[OFF], [ON]
f Factory setting: [OFF]
Adjusts the gamma characteristic adjacent to black.
[−48]...[+48]
f Factory setting: [0]
Adjusts the gamma characteristic of red adjacent to black to the master gamma.
[−20]...[+20]
f Factory setting: [0]
Adjusts the gamma characteristic of blue adjacent to black to the master gamma.
[−20]...[+20]
f Factory setting: [0]
Enables/disables the knee function.
[OFF], [ON]
f Factory setting: [ON]
[80.00%]...[110.00%] (0.25% step)
f Factory setting: [95.00%]
Adjusts the knee point of red to [KNEE MASTER POINT].
[−25.00%]...[25.00] (0.25% step)
f Factory setting: [0.00%]
Adjusts the knee point of blue to [KNEE MASTER POINT].
[−25.00%]...[25.00] (0.25% step)
f Factory setting: [0.00%]
Sets the knee slope.
[00]...[199]
f Factory setting: [130]
Adjusts the knee slope of red to [KNEE MASTER SLOPE].
[−99]...[+99]
f Factory setting: [0]
Adjusts the knee slope of blue to [KNEE MASTER SLOPE].
[−99]...[+99]
f Factory setting: [0]
– 59 –
Description of settings
Description of settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ak-shb800psAk-shu800psAk-shu800e

Table of Contents