Profibus Dp; Application - Siemens SINUMERIK 840D sl Equipment Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Connecting

7.9 PROFIBUS DP

Station name
Unit02
Unit03
7.9
PROFIBUS DP
7.9.1

Application

Connectable devices
The following devices can be connected to the PROFIBUS DP interfaces:
• Distributed I/O
• Drive units with PROFIBUS DP interface (standard slaves)
• S7 controllers with PROFIBUS DP interface
• PG/PC
Properties
• Isolated RS 485 interface
• Max. data rate 12 Mbits/s
• Supports master/slave operation
• PROFIBUS address is set via configuration
Note
In addition to the DP (distributed I/O) protocol, X136 can also transmit the MPI (multi point
interface) protocol (software-controlled).
Pin assignment for X126, X136
Table 7-18
Pin
1
2
3
4
5
6
66
Module type
CPU 319-3 PN/DP
CPU 317-2 PN/DP
PROFIBUS DP interface X126
Signal name
Signal type Meaning
-
-
M
VO
1RS_DP
B
1RTS_DP
O
M5EXT
VO
P5EXT
VO
Interface
PN P1
PN P1
Reserved, do not use
Ground to P24_SERV
RS-485 differential signal
Request to send
Ground to P5EXT
5 V power supply for bus termination, external, short-circuit
proof
Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1
IP address
192.168.200.22
192.168.200.32
NCU 7x0.3B PN