X2 Profinet - Siemens SINUMERIK 840D sl Equipment Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

9.2.3.3

X2 PROFINET

Data Transmission Rate and Cables
For PROFINET, you require a data transmission rate of 100 Mbit/s (Fast Ethernet). The interfaces
are designed for full-duplex mode; in other words, the ports can both transmit and receive. For
data transfer purposes you can use electrical twisted copper cables (twisted pair, 4-wire,
100Base-T):
• The transmission characteristics of these cables must meet the requirements of CAT5.
• The maximum length of the connections between the end device and network component
or between two network components (e.g. switch ports) must not exceed 100 m.
Pin assignment
Table 9-16
Pin
1
2
3
4
5
6
7
8
Cable specification
Table 9-17
Characteristic
Connector type
Cable type
Max. cable length
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and a yellow LED. This
allows the following information to be displayed for the respective PROFINET port:
Table 9-18
Name
Link
NCU 7x0.3B PN
Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1
PROFINET interfaces X2, ports 1, 2
Signal name
Signal type
TX+
O
TX-
O
RX+
I
N.C.
-
N.C.
-
RX-
I
N.C.
-
N.C.
-
Cable specification at X2, ports 1, 2
PROFINET ports LED displays
Color
Status
Green
lit
off
Meaning
Transmit data +
Transmit data -
Receive data +
Reserved, do not use
Reserved, do not use
Receive data -
Reserved, do not use
Reserved, do not use
Version
RJ45 socket
Industrial Ethernet cable (CAT5)
100 m
Meaning
Transfer rate 100 Mbit/s
No or faulty connection
Connectable components
9.2 PP 72/48D PN
107