9.3 PP 72/48D 2/2A PN
16 bit value (hex.)
0x1999
0x0CCC
0x0000
0xF333
0xE666
Underrange
Underflow
Table 9-59
16 bit value (hex.)
Overflow
0x0A28
0x03E8
0x01F4
0x0000
0xFE0C
0xFC18
0xF830
Underflow
Note
If a Pt100 element is accidentally not connected in this operating mode and an input voltage
higher than 0.25 V is output, the analog module automatically switches to the "no operating
mode" operating mode and resets the gain factor to "1". This is signalized in Status Word 0
(channel-specific) in the input image. In addition, a corresponding error code is output in the
diagnostics slot at a counter value of "2".
In the case of operation without a Pt100 element, a slightly negative voltage may be applied,
which results in an error status for the module. Here, the "PNFault" LED and the status byte 1 are
to be observed.
Analog outputs
Table 9-60
16 bit value (hex.)
Overflow
Overrange
142
16 bit value (dec.)
6553
3277
0
-3277
-6553
Measured values in the "temperature measurement" operating mode
16 bit value (dec.)
2590
1000
500
0.0
-500
-1000
-2000
Measured values in the "voltage output" operating mode
16 bit value (dec.)
Factor
0.00305
-
-
Factor
0.1
Factor
-
-
Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1
Current value [V]
20 mA
10 mA
0 mA
-10 mA
-20 mA
Up to -23.5 mA
Deactivation
Temperature value [V]
259 ℃
100 °C
50 ℃
0 °C
-50 ℃
-100 °C
-200 ℃
Voltage value [V]
Deactivation
Up to 10.5 V
NCU 7x0.3B PN