Maintenance; Water Treatment System; Removal Of Lime Scale Deposits; Items Required (Not Provided) - Vulcan-Hart C24EA Series Installation & Operation Manual

Electric counter convection steamers
Hide thumbs Also See for C24EA Series:
Table of Contents

Advertisement

C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS
The steamer and its parts
are hot. Use care when operating, cleaning
or servicing the steamer. The cooking
compartment contains live steam and hot
water. Stay clear when opening the door.

WATER TREATMENT SYSTEM

A water treatment system is recommended for
the steamer. Refer to your supplier's manual
for normal maintenance procedures for proper
scale-free operation.
REMOVAL OF LIME SCALE
DEPOSITS
The steamer should be delimed when symptoms
occur (see Troubleshooting Chart). This is
in accordance with the minimum preventive
maintenance schedule required by the Warranty.
Read and follow the
instructions on the deliming material
package. Avoid contact with skin and eyes.
Wear plastic or rubber gloves and safety
goggles when handling. Wash thoroughly
after handling. If deliming solution comes
in contact with the skin or eyes, rinse
thoroughly with clean water.
The steamer and its parts
are hot. Use care when operating, cleaning
or servicing the steamer. The cooking
compartment contains live steam and hot
water. Stay clear when opening the door.

MAINTENANCE

Items Required (Not Provided):

Deliming material, (1 bag of scale release
Vulcan part number 854893-13)
Plastic or rubber gloves
Safety goggles or face shield
1-gallon container for mixing deliming
solution
Petrol-Gel Lubricant or equivalent food-
grade grease for coating deliming port
threads
surface of aluminum measuring tools to
tarnish or etch.

Professional Unit (Automatic Drain)

to take the place of a water treatment
program.
1. Turn power switch OFF. Wait 5 minutes for
steam generator to completely drain and the
drain valve to close.
2. Turn cooking timers to OFF.
3. Prepare deliming solution according to the
instructions on the deliming material package.
Follow all manufacturer's instructions.
4. Remove delime port cap on top of unit and
insert funnel into delime port (Figure 4).
— 14 —
Deliming solution will cause the
This procedure is not intended
Figure 4

Advertisement