ENTER READING CONFIGURATION MENU:
Press a
Press d
Press a
Press d
DECIMAL POINT SUBMENU:
Press d
Press b
Press d
KNOWN/UNKNOWN LOADS SUBMENU:
Press d
Press b
Press d
LINEARIZATION POINTS SUBMENU:
Press d
Press b
Press d
1) Press a , if necessary, until CNFG prompt appears.
2) Display advances to INPT Input Menu.
3) Display advances to RDG Reading Configuration Menu.
4) Display advances to DEC Decimal Point.
5) Display flashes previous selection for Decimal location.
6) Scroll though the available selections and choose Decimal
location: FFFF , FFF.F , FF.FF or F.FFF
7) Display shows STRD stored message momentarily only, if
changes were made, otherwise press a to advance to LOAD
Known/Unknown Loads Submenu.
Decimal Point is passive.
8) Display flashes previous selection of ENBL Enable or DSBL
Disable.
9) Scroll though the available selection of ENBL or DSBL
(flashing).
10) Display shows STRD stored message momentarily and then
advances to L.PNT Linearization Points Submenu.
If ENBL Known Loads scaling method was selected, calculate
the input values to the instrument based on the actual signal
being received. If DSBL Without Known Loads scaling method
was selected, calculate input values to the instrument based on
the transducer specification.
11) Display flashes previous selection of Linearization Points
Submenu.
12) Scroll though the available selections: 0002 , 0003 , 0004 ,
0005 , 0006 , 0007 , 0008 , 0009 , 0010 - up to 10
Linearization Points can be selected. Default is 0002 .
If display flashes NONE , your instrument has only 2 linearization
points.
13) Display shows STRD stored message momentarily only, if a
change was made, otherwise press a to advance to the FLTR
Filter Constant Submenu.
Linearization Points allow users to customize the Transducer curve.
19