7.
Start­up
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up if the required instructions are not to hand.
7.1
Procedure before start­up
7.1.1

Removal of preservative agent

The location of the oil­draining points is marked by a symbol in the dimensioned drawing in the gear­unit
documentation.
Oil­draining point:
Place suitable containers under the oil­draining points.
Unscrew the oil­drain plug or open the oil­drain cock.
Remove remaining preservative agent and/or running­in oil from the gear unit using a suitable
container, unscrew any existing residual­oil drain plugs, to do so.
Dispose of remaining preservative agent and/or running­in oil in accordance with regulations.
Remove any oil spillage immediately with an oil­binding agent.
The oil must not come into contact with the skin (e.g. the operator's hands).
The safety notes on the data sheets for the oil used must be observed here!
Screw in oil­drain plug or reclose oil­drain cock.
Screw in any unscrewed residual­oil­drain plugs again.
3
Fig. 21: Oil inlet/oil drain gear unit
1
Inspection and/or assembly cover
2
Oil dipstick
3
Breather screw or screw plug
1
2
4
4
Oil­drain plug
5
Oil inlet
BA 5200 EN 08/2010