7.2.8

Checking procedure

The following visual checks must be conducted and recorded when starting up:
Oil level
Leaktightness of the oil­cooling or oil­supply lines
Opening condition of the shut­off valves
Effectiveness of the shaft seals
Freedom of the rotating parts from contact
7.3

Removal from service

Switch off drive unit.
Secure the drive unit to prevent it from being started up unintentionally.
Attach a warning notice to the start switch!
Close the stop valves in the coolant in­ and outflow pipes (on gear units with oil­cooling system only).
In the case of water oil­cooler, drain the water. Frost hazard!
Start the gear unit and allow it to run briefly (5 to 10 minutes) approx. every 3 weeks (during a shut­down
period no longer than 6 months).
Treat the gear unit with preservative, see items 7.3.1 and 7.3.2 (before a shut­down period exceeding
6 months).
7.3.1

Interior preservation during longer disuse

Depending on the type of lubrication and/or shaft sealing, the following types of interior preservation can
be applied.

7.3.1.1 Interior preservation with gear oil

Gear units with splash­lubrication systems and contacting shaft seals can be filled with the correct type of
service oil up to a point just below the air filter.

7.3.1.2 Interior preservation with preservative agent

Before longer shut­down periods gear units with forced lubrication systems, oil circulation cooling and/or
non­contacting shaft seals should be filled with preservative agent and run without load.
BA 5200 EN 08/2010
51 / 65