Maintenance
1. Jam nut
2. Linkage rod
3. Impeller shaft
4. 1/8 inch (3.2 mm) gap between ramp tooth and impeller
shaft
5. Ramp tooth
5.
Pull the linkage rod until there is 1/8 inch (3.2
mm) gap between the ramp tooth and the impeller
shaft.
6.
Tighten the jam nut.
Adjusting the Gate Closure
1.
If the gate arm is not fully closing, adjust the
control cable:
• knob located on the cable mount bracket
• nuts located on either side of the hopper
bracket
2.
Continue to adjust until the gate can be fully
closed; retighten all components.
Figure 21
Cleaning
Clean Debris From Machine
Service Interval: Before each use or daily
1.
Stop engine, wait for all moving parts to stop, and
remove key. Engage parking brake.
2.
Clean off any debris or build-up on the machine,
especially the impeller.
g027205
22