Swinger Shutdown Count; System Options - Bosch Solution 6+6 Wireless AE Quick Reference Manual

Table of Contents

Advertisement

Solution 6+6 Wireless - AE
Location 170 - 171
Entry Guard Timer (Seconds, 16 Seconds)
Location 172 - 173
Sensor Watch Time (Days)
Location 174
Codepad Lockout Time (10 Second)
Location 175
Siren Run Time (Minutes)
Location 176
Siren Sound Rate (Slow <-Sound-> Fast)
Location 177

Swinger Shutdown Count

Location 178
Dialler Options 1
Location 179
Dialler Options 2
Location 180

System Options 1

Location 181
System Options 2
Location 182
System Options 3
Location 183
System Options 4
Location 184
Consumer Options 1
Location 185
Consumer Options 2
Location 186 - 191
Area 1 Zone Allocations
Page 12
Quick Reference Guide
1 = Enable Dialler Reporting Functions
2 = Enable Remote Arming Via The Telephone
4 = Enable Remote Connect Via Upload/Download Software
8 = Terminate "Upload/Download" Session On Alarm
1 = Send Open/Close Reports Only If A Previous Alarm Has Occurred
2 = Enable First To Open, Last To Close Reporting (Partitioning Only)
4 = Send Open/Close Reports When In STAY Mode
8 = Delay Siren Until Transmission Is Complete
1 = Enable Forced Arming
2 = Enable Smart Lockout
4 = Enable Monitoring Of Horn Speaker
8 = Allow Horn Speaker Beeps For Radio Remote Control Operation
1 = Enable Radio Key/Keyswitch Interface or Night Arm Station
2 = Enable Handover Delay To Be Sequential
4 = Enable Codepad Panic To Be Silent
8 = Enable Access Denied To Be Silent
1 = Enable Main Codepad To Display Data For Area #1
2 = Enable Resetting Of Sirens From Both Areas
4 = Ignore AC Fail
8 = Enable Handover Of Zone Pulse Count
1 = Enable AC Fail In 1 hour
2 = Extend Time To Wait For Handshake From 30 Seconds To 1 Minute
4 = Enable Control Panel To Power Up In The Disarmed State
8 = Enable Remote Radio Zone Low Battery Reports
1 = Send Test Reports Only When The System Is Armed
2 = Enable Operation Of Siren & Strobe In STAY Mode
4 = Enable Answering Machine Bypass To Work Only When Armed
8 = Enable Codepad Extinguish Mode
1 = Enable "User Code + 0 + AWAY" Function To Arm/Disarm BOTH Areas At The Same Time
2 = Enable Single Button Arming In AWAY and STAY Modes
4 = Enable Single Button Disarming From STAY Mode
8 = Enable Alarm Memory Reset On Disarm
Bosch Security Systems Pty Limited
ISSUE 1.00
12 3
0 0
0
10
7
0
5
0
1
2
0
0
2
0
0 0 0 0 0 0