Connections Of Split EOL Resistors For Tamper Operation
Wiring Diagrams For Keyswitch Zones
Note 1:
When choosing an EOL resistor value other than the default 3K3 for a non-partitioned system, the
keyswitch zone must still use a 3K3 EOL resistor as shown in "Figure 1". The keyswitch zone will not
operate with any other resistor value.
Note 2:
When using a keyswitch zone in partitioning, to enable arming/disarming of Area 2, there is no need to
enable split EOL resistors when not using tamper zones. Simply wire the zone as shown in "Figure 2".
Quick Reference Guide
Figure 1: Wiring Diagram For Keyswitch Zone
Figure 2: Wiring Diagram For Keyswitch Zone In Partitioning