3 SPECIFICATIONS

3.1.3 Coaxial cable specifications

Item
Structure
Cable diameter
Minimum allowable bend radius
Internal conductor diameter
Insulating material diameter
External conductor diameter
Applicable connector plug
3 - 5
The following table lists the specifications of the coaxial cables used for the coaxial bus
system.
The high frequency coaxial cable "3C-2V" or "5C-2V" (conforms to JIS C 3501) is
used.
(1) Coaxial cable specifications
The specifications of the coaxial cable are shown in Table 3.3.
Select coaxial cables that meet the operating ambient temperature (0 to 55 C )
shown in the general specifications of the programmable controller.
Table 3.3 Coaxial cable specifications
3C-2V
5.4 mm (0.21 in.)
22 mm (0.87 in.) or more
0.5 mm (0.02 in.) (annealed copper wire)
3.1 mm (0.12 in.) (polyethylene)
3.8 mm (0.15 in.) (single annealed copper wire mesh)
3C-2V connector plug
(BNC-P-3-NiCAu is recommended.)
REMARKS
Consult the nearest Mitsubishi representative for connector plugs.
Internal
Insulating
conductive
material External
material
conductor
6.6 mm (0.26 in.) (single annealed copper wire mesh)
MELSEC-Q
5C-2V
Outer sheath
7.4 mm (0.29 in.)
30 mm (1.18 in.) or more
0.8 mm (0.03 in.) (annealed copper wire)
4.9 mm (0.19 in.) (polyethylene)
5C-2V connector plug
(BNC-P-5-NiCAu is recommended.)