Interlogix Sentrol DV1201A Installation Manual

Seismic detectors

Advertisement

Quick Links

Sentrol
Figure 1: Wiring diagram
1/2.
12 Vdc
7.
Common (C)
3.
LED indication
8/9.
Tamper
4.
Integrator level
10.
Test control
5.
Normaly Closed (NC)
11.
Spare
6.
Normaly Open (NO)
Figure 3: General characteristics of the DV1201A / DV1221A
Using the mounting plate DV1202A as a template
A.
Holes for DV1201A / DV1221A
B.
Hole for expansion plug or recess mounting box
C.
Template and mounting holes for test transmitter DV1215A
D.
Holes for accessories.
Figure 4: Mounting the detector directly on a metal surface without using a mounting plate
Form: Letter (bookshape)
Formaat: Letter (boekvorm)
White paper: 70gr/m² progresso; overprint black. If P.O.D.: use 80gr/m².
Wit papier: 70gr/m² progresso; opdruk zwart. Wanneer P.O.D.: gebruik 80gr/m².
Manual DV1201A / DV1221A
G. Manders
A4
DV1201A & DV1221A
Seismic Detectors Installation Manual
Figure 2: Two ways to test the seismic detectors
Test disabled (ex-factory setting)

Internal test of detector's electronics =
Position jumper between 1 and 2 .
Function test of the detector and its physical contact
with the protected object = Position connector from
test transmitter DV1215A between 2 and 3.

Connecting terminal 10 to 0 V activates both tests.
1.
Cover
2.
Cover screw
3.
Base plate
4.
Mounting holes
5.
Clamp
6.
Area for mounting the
DV1215A test transmitter
7.
Potentiometer for adjusting
the detector's sensitivity
8.
Connection block
9.
Anti-tamper micro-switch
10. Mounting plate DV1202A
11. Fixing bolt
12. Expander bolt
13. Test transmitter DV1215A
- 1 -
24-04-'02
1 A 2 4 - 0 4 - ' 0 2
5620
14
999-
110-01
1 0 4 2 3 - 1 0 4 2 4

Advertisement

loading

Summary of Contents for Interlogix Sentrol DV1201A

  • Page 1 Sentrol DV1201A & DV1221A Seismic Detectors Installation Manual Figure 2: Two ways to test the seismic detectors Figure 1: Wiring diagram € Test disabled (ex-factory setting)  Internal test of detector’s electronics = Position jumper between 1 and 2 . ‚...
  • Page 2 DV1201A & DV1221A Sentrol Seismic Detectors Installation Manual Figure 2: Two ways to test the seismic detectors Figure 1: Wiring diagram Test disabled (ex-factory setting) " Internal test of detector’s electronics = Position jumper between 1 and 2 . Function test of the detector and its physical contact 1/2.
  • Page 3 Figure 5: Mounting on concrete Always use a DV1202A mounting plate. The expansion plug must penetrate at least 50 mm into the concrete. Please follow the steps shown in Figure 6 if you are installing the test transmitter DV1215A. For the equipment to conform to CEI standard 79-2, the DV1215A test transmitter must be installed.
  • Page 4 Figure 7: Wiring the DV1201A/DV1221A into Most Security Systems Figure 8: Connecting the DV1201A to a Four-wire Circuit Figure 9: Connecting the DV1201A to a Two-wire Balanced Type Control in an UL Complete Mercantile Safe System Loop Type Control in an UL Complete Mercantile Safe System Figure 10: Wire Diagram DV1208A - 3 -...
  • Page 5 Figure 11 © Sentrol is an Interlogix company. 2002. All rights reserved. - 4 - 5620-1A...

This manual is also suitable for:

Sentrol dv1221a