2-3. DELIMING WATER PAN
AND BAFFLES (Continued)

2-4. CLEAN WATER STRAINER

2-5. REPLACE WATER STRAINER 1. Shut off water supply.
2-2
5. Clean the baffles and water pan with a brush, or other tool, to
loosen and remove any buildup. If the buildup is excessive, a
liquid chemical lime remover may help to remove lime.
Do not use steel wool, other abrasive cleaners or
cleaners/sanitizers containing chlorine, bromine, iodine or
ammonia chemicals, as these will deteriorate the stainless
steel material and shorten the life of the pan and baffles.
6. After removing all lime buildup, rinse pan and baffles, and place
water pan and baffles back into cabinet. Make sure water pan
is secure against the ceiling of the cabinet.
7. Replace the top drawer.
8. Reconnect electrical supply to cabinet.
1. Shut off water supply.
2. Remove the hex cap at the bottom of the strainer.
3. Remove the screen from the strainer and clean it. If strainer has a
lime buildup, lime remover can be used.
4. Reassemble in reverse order.
5. Turn on water supply and check for leaks.
Step 2
2. Disconnect water supply tubing.
3. Remove the water strainer, along with the fittings on both ends.
4. Transfer the two fittings from the old strainer to the new one.
Pipe sealant is needed on all threaded fittings.
5. Install the new strainer on cabinet.
6. Reconnect the water supply tubing.
7. Turn on water supply and check for leaks.