Power Switch; Indicating Lights - Henny Penny HCH-930 Technical Manual

Heated holding cabinet
Hide thumbs Also See for HCH-930:
Table of Contents

Advertisement

2-15. POWER SWITCH

2-16. INDICATING LIGHTS

-
2-10
1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove the cabinet top.
3. Remove the wires from the switch. Check for continuity across
the 2 terminals. In the ON position, the circuit should be closed.
In the OFF position, the circuit should be open. If the switch is
defective, continue with the following steps.
4. Loosen the nut securing the switch on the back side of the control
panel, and then remove the nut on the front of the control panel.
5. Remove the switch from the unit.
6. Install the switch in reverse order.
Step 4
7. Replace cabinet top.
8. Reconnect electrical supply to the cabinet.
1. Disconnect the electrical supply to the cabinet.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
2. Remove the cabinet top.
3. Cut the light wires just behind the body of the light.
4. Remove the light by squeezing the retainers on the body and push-
ing the light out through the front of the control panel.
5. Install new light by pushing it through the front of the control panel
until it snaps into place.
Step 4
6. Strip ends of cut wires and connect to new light wires.
7. Replace cabinet top and reconnect electrical supply to cabinet.
Model HCH-930/932
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hch-932

Table of Contents