5.2 Wiring of Network

For the wiring of the network, use the LAN cable of the Category 5e shielded cable type. To
prevent the cable from coming off, securely connect the connector of the cable to the network
connector (RJ45 connector) of the unit.
The length between each node should be within 100 m, and the total length of the
communication loop should be within 200 m.
● Connect the cable that is connected to the "TX" of the GM1 Controller to the "X2A Connector
(RX) "of the servo amplifier. In the same way, connect between amplifiers from X2B (TX) to
X2A (RX).
● Connect them in a loop in such a way that X2B (TX) of the end amplifier is connected to the
"RX" of the GM1 Controller.
● Always use shielded twisted pair (STP) cables that are compatible with category 5e or
higher.
● Turn OFF the power to the system before wiring cables.
● The Ethernet hub cannot be used.
● For detailed information of cable specifications and precautions, refer to the data "RTEX
Cable" listed on the web page.
https://industrial.panasonic.com/ac/e/dl_center/manual/
WUME-GM1H-01

5.2 Wiring of Network

5-5