Setup
7.6.2 Setting the operating pressure
The operating pressure is 6 bar.
Fig. 88: Setting the operating pressure
(1) - Pressure gage
To set the operating pressure:
1. Pull the rotary handle (2) down and turn it.
The operating pressure is indicated on the pressure gage (1).
7.6.3 Lubricating wicks and felt
The wicks and felt in the sewing head must be soaked with oil when setting
up the machine, and especially after longer standstill periods.
Fig. 89: Lubricating wicks and felt
(1) - Wicks
To lubricate the wicks and felt:
1. Release the screws on the head cover.
2. Remove the head cover.
Operating Instructions 806N-111/806N-121 - 04.0 - 12/2020
①
• Increase pressure: turn clockwise
• Reduce pressure: turn counterclockwise
②
Rotary handle
①
②
①
(2) - Felt
121