Installing the Device
2.6.2 Wiring Examples
7.
8.
2.6.2

Wiring Examples

The following illustrate how to connect power to single and dual power supplies.
22
Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power
source to the chassis ground connection on the device. Make sure the lug is
tightened to 1.7 N·m (15 lbf·in).
1
Stainless Steel Stud
1
#6-32 Screw
2
#6 Ring Lug
3
Figure 2.7
Chassis Ground Connection
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the
device is powered.
Install the terminal block cover.
2
3
RUGGEDCOM RSG2288
Installation Manual, 04/2021, C79000-G8976-1045-17