Connecting Power

The RUGGEDCOM RSG2288 supports a single or dual redundant AC and/or DC power
supplies.
The RUGGEDCOM RSG2288 can be equipped with either a screw-type or pluggable
terminal block, which provides power to both power supplies. The screw-type
terminal block is installed using Phillips screws and compression plates, allowing
either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable connections under severe shock or vibration.
Electrical hazard – risk of damage to the device
Make sure power input to the device is within the specified input range. For
information about the nominal input range for the device, refer to
Specifications (Page
Note
RUGGEDCOM RSG2288
Installation Manual, 04/2021, C79000-G8976-1045-17
[Optional] Connect a lightning arrestor, line amplifier or bandpass filter to the
antenna.
1
2
RUGGEDCOM RSG2288
1
Shielded Coaxial Cable
2
Lightning Protector, Line Amplifier or Bandpass Filter
3
GPS Antenna
4
Figure 2.5
Antenna and Lightning Protector Assembly (Optional)
Using shielded coaxial cables, connect the antenna assembly to the GPS IN port
on the device.
NOTICE
37)".
For maximum redundancy in a dual power supply configuration, use two
independent power sources.
Use minimum #16 gage copper wiring when connecting terminal blocks.
For 100-240 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
3
2
Installing the Device
2.6 Connecting Power
4
"Power Supply
19