Summary of Contents for Endress+Hauser Proline Promass 200
Page 1
Solutions Services XA00156D/06/EN/03.13 71214940 Safety Instructions Proline Promass 200 NEPSI Zone 1, Zone 0/1, Zone 21 (Ex i version) Document: XA00156D Safety instructions for electrical apparatus for explosion-hazardous areas classified according to National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (NEPSI)
Explosion-protection brochure: documentation CP021Z/00 The Explosion-protection brochure is available: • In the download area of the Endress+Hauser website: www.endress.com → Download → Advanced → Documentation Code: CP021Z • On the CD for devices with CD-based documentation COC certificates of confor-...
Page 5
Proline Promass 200 • Basic specifications The features that are absolutely essential for the device (mandatory features) are specified in the basic specifications. The number of positions depends on the number of features available. The selected option of a feature can consist of several positions.
• Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Endress+Hauser. • Observe all the technical data of the device (see nameplate). • When using in hybrid mixtures (gas and dust occurring simultaneously), observe additional measures for explosion protection.
Proline Promass 200 • The device can be connected to the Endress+Hauser FXA291 service tool when area is known to be non hazardous. Refer to the Operating Instructions. • Basic specification, Position 3 (Output) = A, B, C, G – When the intrinsically safe Ex ia circuits of the device are connected to certified intrinsically safe circuits of Category Ex ib for Equipment Groups IIC or IIB, the type of protection changes to Ex ib IIC or Ex ib IIB.
Proline Promass 200 Temperature tables: Ambient temperature Compact version Minimum ambient temperature: T = –40 °C Maximum ambient temperature: T = 60 °C depending on the medium temperature and temperature class Medium temperature Minimum medium temperature: • Promass E: T = –40 °C...
Page 9
Proline Promass 200 Output (basic specification, position 3) Approval NEPSI NF, N4 (Basic specification, positions 1, 2) Sensor type [°C] [85 °C] [100 °C] [135 °C] [200 °C] [300 °C] [450 °C] Promass E 200 Promass F 200 For installation with overvoltage protection (OVP) in connection with temperature class T5, T6: T - 2°C...
Proline Promass 200 Explosion hazards arising Determining the temperature class and surface temperature with the temperature from gas and dust table • In the case of gas: Determine the temperature class as a function of the ambient temperature T and the medium temperature T •...
Proline Promass 200 Connection data: Signal The following table contains information that depends on the transmitter type and the circuits (intrinsically safe assignment of the inputs and outputs. Compare the following information to the circuits) information on the nameplate of the transmitter.