Figure 2 Output Tray Full Sensor (Top Right View)
Replacement
NOTE: When re-installing the Main PWB make sure the ground screw, with large head, is rein-
stalled in the correct location.
Install the components in the reverse of removal.
Xerox® Phaser® 3052/3260 Service Manual

REP 1.21 WNPC (WiFi) PWB

Parts List on PL 1.1
Output Tray Full Sensor
Removal
1.
Switch Off the Printer and disconnect the Power Cord.
2.
Remove the following covers:
a.
b.
c.
3.
Disconnect the following connectors from the Main PWB
a.
b.
Control Panel Connector
June 2014
4-31
Remove the Left and Right Side Covers
Remove the Rear Cover
(REP
1.4).
Remove the Top Cover
(REP
1.3).
Control Panel Connector.
WNPC PWB Connector.
Figure 1 Main PWB Connectors to Disconnect
(REP
1.2).
(Figure
1):
WNPC Connector
Repairs