Section 3-3-1: Venting Layout: Wall Mounted Termination

If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Selection of components and details of venting layout should adhere
to the following guidelines:
Vent terminations must not be recessed in walls or siding.
For Heat Shield requirements see Section 3-3.
Once the proposed venting layout has been determined refer to
graph to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
All measurements for vertical or horizontal runs are measured from
center of the vent pipe.
Venting runs must fall within the limits set by the venting graph.
Wall mounted Terminations:
terminations. See below.
Hearth
Figure 8.
XG0228 - 021419
Heat Shield
Termination
41½" Min.
Exterior
Wall
Figure 8.d
Installation
132
120
within non-shaded area.
96
72
60
36
12
0
0
12
36
60
72
Horizontal Run (In.)
Figure 8.b
15' Max.
for minimum
vertical
Flex
Section
72"
within shaded area.
96
120
132
156
Heat Shield
Termination
Rigid
Section
8½' Min at Max.
Horizontal
Exterior
Wall
13