Extreme Networks ExtremeSwitching X440-G2 Series Hardware Installation Manual page 102

For switches using extremexos 21 or 22
Hide thumbs Also See for ExtremeSwitching X440-G2 Series:
Table of Contents

Advertisement

Table 36: STK-RPS-150PS LED Status Definitions
Power LED
Green, solid
Off
For technical specifications, see
STK-RPS-1005PS Redundant Power Supply
Notice
Extreme Redundant Power Supplies (RPS) do not support the ability for the RPS to be
connected to an operational switch. Connecting an RPS to an operational switch can have an
adverse effect on the switch. It is best practice that both the switch and the RPS be powered
down prior to cabling them together. Once the cabling is completed, turn on the RPS, then
turn on the switch.
The STK-RPS-1005PS provides load sharing, backup, or additive PoE power to some Extreme Networks
802.3at PoE-compliant stackable switch models. If the switch loses power from its internal power
supply, the STK-RPS-1005PS can provide up to 1005 W maximum operating power (180 W system
power and 740 W PoE power) to support switch operation and the 55 VDC necessary to support 55
VDC/data connections to powered devices.
The power supply ships with the following:
AC power cable
RPS cable
Four rubber feet (for flat surface installation)
The STK-RPS-1005PS is compatible with the ExtremeSwitching X440-G2-48p-10GE4 switch.
Figure 100: STK-RPS-1005PS Front Panel
ExtremeSwitching and Summit Switches: Hardware Installation Guide
Meaning
AC input to power supply is within
specifications
AC input power to power supply is out
of specification.
STK-RPS-150PS and RPS Shelves Technical Specifications
Power Supplies for Use with Your Switch
Recommended Action
None
1
Check AC power cord connection to the
power supply.
2
Check AC power at the power outlet.
3
Swap power cord for a known good one.
4 If the problem persists, contact Extreme
Networks for support.
on page 387.
102

Advertisement

Table of Contents
loading

Table of Contents