Technical specifications
Article number
Diagnostic buffer
•
present
•
Number of entries, max.
of which powerfail-proof
–
Traces
•
Number of configurable Traces
Interrupts/diagnostics/status information
Diagnostics indication LED
•
RUN/STOP LED
•
ERROR LED
•
MAINT LED
Monitoring of the supply voltage (PWR-LED) Yes
•
•
Connection display LINK TX/RX
Supported technology objects
Motion Control
•
Number of available Motion Control re-
sources for technology objects
•
Required Motion Control resources
per speed-controlled axis
–
per positioning axis
–
per synchronous axis
–
per external encoder
–
per output cam
–
per cam track
–
per probe
–
•
Positioning axis
Number of positioning axes at motion
–
control cycle of 4 ms (typical value)
Number of positioning axes at motion
–
control cycle of 8 ms (typical value)
Controller
•
PID_Compact
•
PID_3Step
•
PID-Temp
Counting and measuring
•
High-speed counter
38
6ES7510-1DJ01-0AB0
Yes
1 000
500
4; Up to 512 KB of data per trace are possible
Yes
Yes
Yes
Yes
Yes; Note: The number of technology objects
affects the cycle time of the PLC program; selec-
tion guide via the TIA Selection Tool
800
40
80
160
80
20
160
40
5
10
Yes; Universal PID controller with integrated op-
timization
Yes; PID controller with integrated optimization
for valves
Yes; PID controller with integrated optimization
for temperature
Yes
CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0)
Equipment Manual, 05/2021, A5E03506268-AD