4.6 HORIZONTAL ROTATION TRAVEL STOPS

The range of horizontal rotation travel for the manual Typhoon monitor is continuous 360 degrees. The motorized version is limited to
450 degrees total horizontal rotation travel, or 225 degrees from either side of a straight ahead position. Horizontal rotation travel stop
bolts may be installed in the monitor to limit travel. Note that left and right are relative to the "Straight Ahead Reference Mark" (the
Straight Ahead Reference Mark and refer to the nozzle's discharge direction as seen from an operator's position behind the nozzle.
Figures 4.6A and 4.6B show the range of travel for the various stop bolt locations and give installation notes.
LOCATION OF STRAIGHT AHEAD
REFERENCE MARK
90°
225°
LEFT
LEFT
135°
LEFT
To change the Horizontal Rotational Travel Limits:
1. Remove the Set Screw
2. Insert 1 Adjustment Disc (Not included. Contact tft.com for parts)
in the bolt hole for every 10° of travel limitation
3. Replace the Set Screw with the Stop Bolt
©Copyright Task Force Tips LLC 2004-2020
45°
45°
LEFT
RIGHT
90°
RIGHT
135°
RIGHT
Figure 4.6A
Horizontal Rotation Travel Limits
10° LESS RIGHT TRAVEL WITH
EVERY ADJUSTMENT DISC
INSTALLED ON THIS SIDE OF
THE STOP BOLT
Figure 4.6B
Horizontal Rotation Travel Stops
RC MODELS WITH NO STOP BOLTS
INSTALLED HAVE A HORIZONTAL
ROTATIONAL TRAVEL LIMIT OF
225° LEFT AND RIGHT OF THE
STRAIGHT AHEAD REFERENCE MARK
MANUAL MODELS WITH NO STOP BOLTS
INSTALLED HAVE A CONTINUOUS
360° HORIZONTAL ROTATIONAL TRAVEL
225°
RIGHT
45°
RIGHT
90°
RIGHT
SET SCREW
STOP BOLT
17
45°
LEFT
90°
LEFT
135°
LEFT AND RIGHT
10° LESS LEFT TRAVEL WITH
EVERY ADJUSTMENT DISC
INSTALLED ON THIS SIDE OF
THE STOP BOLT