Main wash
If you select
altered:
Temperature
Final rinse temp.
-
/
Adjust the temperature for the selected block.
Holding time
-
Adjust the holding time for the selected block.
Select an option using the and arrow buttons and confirm your
selection with OK.
Temperature
50
(30 - 70
The setting value is entered in increments of 1. The possible range is
shown in the bottom line of the display.
Dispensing of process chemicals occurs at a default dispensing
temperature set at the factory. If process chemicals are to be
dispensed in this wash block, the lowest temperature that can be set
will be the dispensing temperature. It is not possible to set a lower
value.
Use the (higher) and (lower) arrow buttons to set the value.
Press OK to save the setting.
Final rinse
or
, the following settings can be
Reset
Temperature
Holding time
°C
°C)
Further settings
Holding time
3
Min
(1 - 10
Min
)
85