3.2.1.3 Test the connection

Use the Connect screen to test the connection. Click on the appropriate station and click
Connect to initiate a call to the data logger. The data logger must have 12 V power.
TIP:
The connection time is subject to many external factors. It is often less than 30 seconds but
could be up to 15 minutes. Be patient.
If the connection is successful, the connectors at the bottom of the screen will come together and
clock information from the data logger will be displayed in the Station Date/Time field. If the
connection fails, a Communications Failure message will be displayed.

3.3 Cellular (TX/RX) LED Indicator

When the data logger is powered, the cellular LED will turn on according to cellular modem
communications states:
Off: Cellular modem off, insufficient power, or failure to establish a connection with the
l
provider (periodic retries will occur).
Solid: Cellular modem is powering up and attempting to establish a connection with a
l
provider.
Quick Flashing (approximately 1 second duration): Indicates successful network
l
registration.
Flashing: Flashes with network activity.
l

3.4 Signal strength

Signal strength may indicate the quality of connection to a cellular tower. For 3G networks, this is
reported as RSSl (Received Signal Strength Indicator). For 4G, it is RSRP (Reference Signal
Received Power).
Signal strength units are –dBm; –70 is a stronger signal than –100.