American Dynamics SpeedDome Ultra VIIE Installation And Service Manual page 14

American dynamics speeddome ultra vii security camera: install guide
Hide thumbs Also See for SpeedDome Ultra VIIE:
Table of Contents

Advertisement

6. Connect the 4-pin plug (alarm input/output) to
the 4-pin receptacle (Figure 14).
a. Feed the cable through the access hole in
the base.
b. Connect alarm wires to the 4-pin plug (refer
to chart below).
c. Insert the plug into the mating receptacle in
the top of the housing and eyeball assembly.
Alarm connections
Pin
Color
1
2
3
4
Figure 14. Cable connections (Manchester
requires separate cables for data and
power)
9-pin plug
LEDs CR2,
CR3, and CR4
visible through
opening.
SPEEDDOME ULTRA VII AND ULTRA VIIE CAMERA DOME
INSTALLATION AND SERVICE GUIDE
Designation
+12Vdc
Alarm Out
Alarm In
Common
4-pin plug
7. Connect the housing and eyeball assembly to
the base (Figure 15) by aligning the Cap and
Base tabs and then turning clockwise until you
hear a click.
Figure 15. Connecting housing and eyeball
assembly to base (cables and
lanyard not shown)
8. Apply power and wait a few seconds for the
dome to begin its homing routine. The homing
routine indicates that address was placed into
dome memory and that dome is ready for
programming.
Note: If the homing routine does not occur or if
the dome does not respond to commands,
check the cable wiring by referring to the LED
response tables in Appendix A.
14 of 38
Align tabs on
Turn clockwise
Cap and Base.
to latch
8200-0184-01, REV. E