P1 connector (Manchester data)
Pin
Color
Designation
1-4
Not used.
5
Black
Manchester (+)
6
White
Manchester (–)
P1 connector (RS422 data)
Pin
Color
Designation
1
Orange
RS422 Data In High (+)
2
Green
RS422 Data In Low (–)
3
Yellow
RS422 Data Out High (+)
4
Brown
S422 Data Out Low (–)
5-6
Not used.
P1 connector (SensorNet 485 data)
Pin
Color
Designation
1-4
Not used.
5
Orange
SensorNet 485
6
Yellow
SensorNet 485
8. If using RS422 network and an I/O board is
used, check comm. line connections by
pressing and holding data test switch SW1
(Figure 21) and observing nearby red and green
LEDs. These LEDs indicate the following:
Constant green,
Comm. line correctly
Blinking red
wired.
Constant green,
"Data In -" shorted to
No red
ground.
Constant red,
"Data In +/ -" wires
Blinking green
reversed.
Blinking red,
"Data In +" shorted to
Green off
ground.
Both LEDs off
"Data In +/ -" wires
shorted or open.
INSTALLATION AND SERVICE GUIDE
9. Check spring finger connector on I/O board by
connecting housing and eyeball assembly to
original base to verify contact between spring
fingers and CPU board (under cap). Does dome
produce video and respond to commands?
YES Spring fingers may not have seated
properly. Reconnect housing and eyeball
assembly.
NO
Replace I/O board.
If routine troubleshooting did not solve the problem,
the manufacturer strongly recommends you ship
the entire dome (including base, if an I/O board is
used) to the National Service Center (NSC) for
service. See page 22 for phone numbers.
If you must perform detailed troubleshooting, use
extreme care when disassembling parts! See
"Detailed Troubleshooting," next.
25
DeltaDome II Camera Dome
8000-2708-01, REV. B