American Dynamics AD715LS Series Installation And Service Manual page 14

Deltadome ii programmable surveillance camera
Hide thumbs Also See for AD715LS Series:
Table of Contents

Advertisement

3. WITH POWER OFF, connect video cable
(Figure 12).
a. Connect BNC of video micro coax cable
6003-0131-01 to BNC of video cable.
b. Feed cable through access hole in base.
c. Press micro coax connector into mating
receptacle in top of housing and eyeball
assembly. A firm snap indicates a tight
connection.
4. If dome is connected at end of comm. line, set
termination jumper JW1 (Figure 12).
Jumper JW1 is pre-installed across pins 1-2
(unterminated). These pins are closest to 9-pin
connector. If dome is to be connected at end of
a communications line, place jumper across
pins 2-3 (terminated).
You may need a small slotted screwdriver to
gently pry jumper loose. Be careful not to
damage underlying PC board.
Figure 12. Video cable connection and
termination jumper location
Micro
Coax
Cable
INSTALLATION AND SERVICE GUIDE
Termination
Jumper JW1
14
5. Connect 9-pin plug (data and power) to 9-pin
receptacle (Figure 13).
CAUTION: DO NOT connect 9-pin plug unless
you have performed step 3 first!
a. Feed cables through access hole in base.
b. Connect data and power wires to 9-pin plug
(refer to charts below).
c. Insert plug into mating receptacle in top of
housing and eyeball assembly.
Manchester data and power connections
(Ultra IV only). Order data cable 88760
(plenum) or 8760 (non-plenum) from Belden by
calling 1-800-235-3361.
Pin
Color
1
White
2
Black
3
Black
4
Red
5
White
6-9
RS422 data and power connections
Pin
Color
1-2
3
Black
4
Red
5
White
6
Orange
7
Green
8
Yellow
9
Brown
SensorNet data and power connections
Pin
Color
1
Orange
2
Yellow
3
Black
4
Red
5
White
6-9
Designation
Manchester (–)
Manchester (+)
24Vac
Ground
24vac
Not used.
Designation
Not used.
24Vac
Ground
24Vac
RS422 Data In High (+)
RS422 Data In Low (–)
RS422 Data Out High (+)
RS422 Data Out Low (–)
Designation
SensorNet (unshielded)
SensorNet (unshielded)
24Vac
Ground
24Vac
Not used.
DeltaDome II Camera Dome
8000-2708-01, REV. B