Downloading Phone Number

[59] 6th System Option Code

[1] PGM Squawk on Exit Options
On = PGM Squawk on Exit Delay.
The PGM output will pulse during the Exit Delay Time. If
the Urgency on Exit Delay function described below is
enabled, the PGM pulse will be quickened for the last 10
seconds of the Exit Delay.
* Off = No PGM Squawk on Exit Delay.
[2] PGM Squawk on Entry Options
On = PGM Squawk on Entry Delay.
The PGM output will pulse during the Entry Delay Time. If
the Urgency on Entry Delay function described below is
enabled, the PGM pulse will be quickened for the last 10
seconds of the Entry Delay.
* Off = No PGM Squawk on Entry Delay.
[3] Audible Exit Fault Enabled / Disabled
* On = Audible Exit Fault Enabled.
If a Delay Zone is left open at the end of the Exit Delay,
the Entry Delay will begin immediately and the bell or
siren will sound a steady alarm. This feature is designed
to immediately alert the user that their system has been
armed incorrectly.
Off = Audible Exit Fault Disabled.
If a Delay Zone is left open at the end of the Exit Delay,
the Entry Delay will begin immediately. If the system is
not disarmed before the end of the Entry Delay, an alarm
will be generated.
[4] Exit Delay Urgency Tone Option
* On = Audible Exit with Urgency.
The Keypad will sound a pulsing tone during the Exit
Delay. During the last 10 seconds of the Exit Delay, the
keypad will sound a faster pulsing tone to warn that the
Exit Delay is about to expire.
Off = Standard Exit Delay.
The Keypad will be silent for the entire Exit Delay.
[5] Entry Delay Urgency Tone Option
* On = Urgency Applied to Entry Delay.
The Keypad will sound a steady tone during the Entry
Delay. During the last 10 seconds of the Entry Delay, the
keypad will sound a pulsing tone to warn that the Entry
Delay is about to expire.
Off = Standard Entry Delay.
The Keypad will sound a steady tone throughout the
Entry Delay time.
[6] Closing Confirmation Enabled / Disabled
On = Closing Confirmation Enabled.
When an Access Code is entered to arm the system, the
Exit Delay time will not begin until one of the following
events occurs:
• The closing is successfully transmitted to the
monitoring station. When the closing is transmitted,
the keypad will sound an acknowledgement tone to
indicate that the monitoring station has been
advised of the closing. The Exit Delay will then
begin.
• The closing is not successfully transmitted to the
monitoring station. If the closing cannot be
transmitted, the Exit Delay will begin and the keypad
will sound trouble beeps. Upon disarming, a "Fail to
Communicate" (Trouble 5) will be displayed.
• The user may re-enter their Access Code to initiate
the Exit Delay
* Off = Closing Confirmation Disabled.
The Exit Delay time will commence once an access code
is entered to arm the system.
Notes:
The following restrictions apply to Closing
Confirmation:
• Split Arming must not be used (sections [31] to
[34]).
• Auxiliary Delay zones must not be used (section
[14]).
• Exit Delay Termination must not be used (section
[59] light 7 OFF).
[7] Exit Delay Termination Enabled / Disabled
On = Exit Delay Termination Enabled.
The Exit Delay will be terminated once the Delay Zone
for the entry/exit door or area is restored. All audible
options associated with the Exit Delay will be silenced
when the Exit Delay is terminated.
* Off = Exit Delay Termination Disabled.
The Exit Delay timer will continue to count even after the
Delay Zone for the entry/exit door or area is restored. All
audible options associated with the Exit Delay will
function until the time programmed for the Exit Delay has
elapsed.
Notes:
The following restrictions apply to Exit Delay
Termination:
• Split Arming must not be used (sections [31] to
[34]).
• Closing Confirmation must not be used (section
[59] light 6 OFF).
[8] For Future Use
* is default condition.
Note: PGM output in section [30] must be configured for
option 'C' for using options 1 and 2 in this section.

[90] Installer's Lockout Enable

This feature is enabled by entering [90] while in the
Installer's Programming mode. A factory default (hardware
or software) will not reset the Installer's Code or the
download access code once this feature is enabled. A panel
that has this lockout feature enabled will give a distinctive
audible indication upon power up. This indication is the
phone line relay clicking ten times. Make sure that your new
Installer's Code has been entered correctly before enabling
this feature because there is no way of re-entering the
programming mode without the new Installer's Code. Even a
reset to the factory default will not change the Installer's
Code back to default.

[91] Installer's Lockout Disable

Entering [91] when in the Installer's Programming mode will
disable the Installer's Lockout feature.
Note: Panels returned to DSC with the Installer's
Lockout feature enabled and no other apparent
problems will be subject to an additional service
charge.