3Rd System Option Code - DSC PC2550 Installation Manual

Hide thumbs Also See for PC2550:
Table of Contents

Advertisement

Bypassed zones will not be identified when the system is
armed; only the Partial Closing Code and the Closing
Access Code will be transmitted.
[2] Master Code Options
On = Master Code Not User-Changeable.
The Master Code may not be changed by the user, and
may only be programmed in the Installer's Programming
Mode.
* Off = Master Code User-Changeable.
The Master Code may be programmed by the user
using the [ ][5][Master Code] command. The Master
Code may also be programmed in the Installer's
Programming Mode.
[3] Bell Squawk Options
On = Bell Squawk on Arming and Disarming.
The bell or siren will sound a single squawk when the
system is being armed, and a double squawk when the
system is being disarmed.
* Off = No Bell Squawk.
The bell or siren will not squawk when the system is
armed or disarmed.
[4] PC16OUT Options
On = PC16OUT Module Enabled.
A PC16OUT module may be connected to the control
panel; refer to the PC16OUT Installation Sheet.
* Off = PC16OUT Module Disabled.
The system will not support the use of a PC16OUT
Module.
[5] Telephone Line Monitor Trouble Options
On = TLM Trouble Only.
A Telephone Line Monitor Trouble will generate a trouble
indication; the "Trouble" light will come ON and the
keypad sounder will beep until the [ ][2] View Trouble
Conditions Command is entered.
Note: The "Trouble" light will not come ON in the
armed state.
* Off = TLM Audible When Armed.
When the system is disarmed, a Telephone Line Monitor
Trouble will generate a trouble indication as described
above. If the system is armed, a Telephone Line Monitor
trouble will generate an audible alarm on the bell or
siren.
[6] Radionics Handshake Frequency Selection
On = 1400Hz Handshake.
The system will accept handshake tones at 1400Hz
when using Radionics communications formats.
* Off = 2300Hz Handshake.
The system will accept handshake tones at 2300Hz
when using Radionics communications formats.
Consult with the monitoring station to determine which
communication formats and handshake frequencies are
required.
[7] Telephone Line Monitor Disabled / Enabled
On = Telephone Line Monitor Disabled.
The TLM function will be shut off and telephone line
troubles will not be indicated by the system.
* Off = Telephone Line Monitor Enabled.
The TLM function will be active and the system will
indicate Trouble Condition 4 when using the [ ][2] View
Trouble Conditions Command.
[8] Bypass and Access Code Options
On = Access Code Required to Bypass Zones.
After entering the [ ][1] Bypass Zones Command, an
access code must be entered before zones may be
bypassed.
* Off = Access Code Not Required to Bypass Zones.
Enter the [ ][1] Bypass Zones Command to bypass zones.
* is default condition.

[17] 3rd System Option Code

[1] Bell During Auto-arm Options
On = Bell During Auto-arm Disabled.
The bell or siren will not be activated during the 1 minute
Auto-arm warning time.
* Off = Bell During Auto-arm Enabled. The bell or siren will
sound a single squawk every 10 seconds during the 1
minute Auto-arm warning time.
[2] AC Trouble Options
On = AC Excluded from Trouble.
If AC power fails, the condition will be reported to the
monitoring station but will not be indicated on the system
keypads.
* Off = AC Trouble Reported and Displayed.
If AC power fails, the condition will be reported to the
monitoring station and will be indicated as a Trouble
condition on the system keypads.
[3] Zone Power-up Options
On = 120 Second Bypass of Zones on Power-Up.
When power is first applied to the system, all zones will
be bypassed for two minutes. This is to allow time for the
detection devices to "settle" without causing false
alarms. After 2 minutes, the zones will be active.
* Off = Zones Active on Power-up.
All zones will be active when power is applied to the
system.
[4] Auto-arm Cancellation Options
On = Auto-arm Cancel Requires Access Code.
An access code must be entered to cancel the Auto-arm
sequence during the 1 minute Auto-arm warning time.
* Off = No Code Required.
Pressing any key during the 1 minute Auto-arm warning
time will cancel the Auto-arming sequence.
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc2550rk

Table of Contents