[02] 1st Account Code

The 1st account code is always transmitted to the 1st phone
number to identify the alarm customer. After entering the
Section number [02], enter a 4 digit number. If "HEX" digits
A to F are required; enter [ ], [1]...[6] and [ ] again to
return keys to normal decimal entry. Where a zero digit in
the account code is required use "HEX A" ([ ][1][ ] to
transmit 10 pulses. The receiver at the monitoring station
interprets 10 pulses for a digit as a zero. If a three digit code
is required as in 3/1 formats, enter [0] as the last digit. [0]
represents a null digit....no pulses transmitted.

[03] 2nd Phone Number

This is the second telephone number to which the
communicator will dial. See section [01] "1st Phone
Number" for programming instructions.

[04] 2nd Account Code

The 2nd account code is always transmitted to the 2nd
phone number. See section [02] "1st Account code" for
programming instructions.

Reporting Codes Explanation

Sections [05] to [13] are used to program the communicator
reporting codes. A reporting code is transmitted along with
the account code with each transmission. If the reporting
codes are not programmed in these sections no
transmission will be sent when an event (i.e. alarm, restoral,
opening/closing, trouble etc.) takes place. To prevent a
transmission from being sent for any event in the following
sections leave it unprogrammed or enter [00] as the
reporting code.
Between 6 to 10 reporting codes are programmed in each
section. Once the section number is entered, the keypad
expects 6 to 10 two digit numbers to be entered for the
number of reporting codes in that section. The keypad
beeps twice and the "Armed" light flashes after each 2 digit
number is entered. After the last code is entered,
programming of the current section is complete. The
keypad will beep 5 times, the "Ready" light will go off and
the "Armed" light will go on. The keypad is then ready to
accept the next section number for programming.
When changing the reporting codes in a section, only code
entries up to the one which is being changed need to be
entered. Press [#] to exit from the programming sequence.
Only codes up to the last one entered will be changed.
[05] Alarm Reporting Codes Zones 1 to
8
Once the Section code [05] is entered, the keypad expects
8 two digit numbers to be entered as the reporting codes for
zones 1 to 8 alarms (restorals in section [06]). These codes
are used by the communicator when there has been an
alarm on zones 1 to 8. Listed below are several
programming examples and the resulting transmission using
different formats for the reporting codes. Obtaining different
formats requires entering data correctly in the account code
section ([02] or [04]) reporting codes sections ([05] to [13],
[50], [54] and [55]) and communication format options,
section ([29]).
3/1 Format....Single Line or Non-extended Reporting
Required:
• 3 digit account code in sections [02] or [04]
i.e. enter [1230] for account code 123
• Format code [0], [1], [2], [3], [4] depending on receiver
type selected in section [29]
• Single digit alarm reporting code in section [05]
i.e. enter [30] for single digit code 3 (0 is null digit i.e. no
pulses transmitted)
Transmission sent:
• 123 3
4/2 Format....Single Line Reporting
Required:
• 4 digit account code in Sections [02] or [04]
i.e. enter [1234] for account code 1234
• Format code [0], [1], [2], [3], [4] depending on receiver
type selected in section [29]
• Two digit alarm reporting code in section [05]
i.e. enter [31] for two digit code 31
Transmission sent:
• 1234 31
3/1 Format....Extended Reporting
Required:
• 3 digit account code in Sections [02] or [04]
i.e. enter [1230] for account code 123
• Format code [8], [9], [A], [B], [C] depending on receiver
type selected in section [29]
• Two digit alarm reporting code in section [05]
i.e. enter [31]
Transmission sent:
• 1st round 123 3
• 2nd round 333 1
If a transmission is not wanted for a particular reporting
code, then enter 00 to disable that reporting code.
[06] Restoral Reporting Codes
Zones 1 to 8
These reporting codes are used by the communicator to
transmit a zone alarm for zones 1 to 8. Use instructions in
section [05] as a guide for programming.