Midi Input Filter - Akai MPC 3000 Operator's Manual

Midi production center
Hide thumbs Also See for MPC 3000:
Table of Contents

Advertisement

MIDI Input Filter

Selecting option 3 from the MIDI key menu presents the MIDI
Input Filter screen, which allows specific types of MIDI events to be
either received or ignored by the MPC3000:
===== Sound Generator Input Filter =====
MIDI volume:RECEIVE
Prog change:IGNORE
======= Sequencer Input Filter =========
Event:NOTES
Pass event?:YES
Velocity mode:NORMAL
========================================
There are two sections, the Sound Generator Input Filter and the
Sequencer Input Filter. The fields are:
The Sound Generator Input Filter section:
• The
MIDI volume
This choice field has two options:
RECEIVE
, incoming MIDI volume messages (controller 7) will
affect the sound generator's overall output volume on all outputs. If
IGNORE
set to
, incoming MIDI volume messages will be ignored.
• The
MIDI vol now
This field shows the last value of MIDI volume (controller 7)
received. A value of 127 is normal (no attenuation). Any value less
than 127 causes the volume of all outputs to be attenuated from
normal. A VALUE OF ZERO WILL SILENCE ALL AUDIO
OUTPUTS EVEN IF ALL OTHER PARAMETERS ARE SET
CORRECTLY!
Prog change
• The
This choice field has two options:
RECEIVE
, incoming Program Change messages will automatically
select the active program. (Incoming Program Change messages
above program 24 will select program 24.) If set to
ing Program Change messages will be ignored.
The Sequencer Input Filter section:
Event
Pass event?
• The
and
The
Event
field is a choice field and can be set to any one of the
following event types:
Page 213
Chapter 11: MIDI Function
MIDI vol now:127
Min change:5
Fixed veloc: 64
field:
RECEIVE
and
field:
field:
RECEIVE
and
fields:
IGNORE
. If set to
IGNORE
. If set to
IGNORE
, incom-

Hide quick links:

Advertisement

Table of Contents
loading