Technical specifications
13.1
Technical specifications for Rack4200
product brand name
Product designation
General technical data:
Equipment marking / acc. to DIN EN 81346-2
Number of slots
Type of power output / connectable
Supply voltage:
Power capacity
without fan / per rack / maximum
•
with fan / per rack / maximum
•
Communication:
Design of the interface
Mechanical data:
Mounting position
Mounting type
Type of ventilation
Vibration resistance
during operation / acc. to IEC 60068-2-6
•
during storage / acc. to IEC 60068-2-6
•
Shock resistance
acc. to IEC 60068-2-27
•
acc. to IEC 60068-2-29
•
Protection class IP
Depth
Height
Width
Electromagnetic compatibility:
EMC emitted interference
Field-bound parasitic coupling / acc. to IEC
61000-4-3
Electrostatic discharge / acc. to IEC 61000-4-2
SIPLUS HCS4200
Operating Instructions, 11/2015, A5E35066204A/RS-AA/002
SIPLUS
Rack4200 for 12 POM
K
12
POM4220
88 kW
193 kW
system interface
horizontal
Control cabinet backplane
Self ventilation or forced ventilation
10 ... 58 Hz / 0.075 mm, 58 ...
150 Hz / 1g
5 ... 8.5 Hz / 3.5 mm, 8.5 ...
500 Hz / 1g
15g / 11 ms / 3 shocks / axis
25 g / 6 ms / 1000 shocks / axis
IP20
293 mm
285 mm
488 mm
Limit value in accordance with IEC 61000-6-4:2007 + A1:2011
10 V/m (80 ... 1000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7
GHz)
4 kV contact discharge / 8 kV air discharge
13
Rack4200 for 4 POM
4
29 kW
64 kW
10 ... 58 Hz / 0.075 mm, 58 ...
150 Hz / 1 g
5 ... 8.5 Hz / 3,5 mm, 8.5 ... 500
Hz / 1 g
204 mm
127