УП "Спецпривод-С". http://www.privod.by/. Email: info@privod.by, msv125@mail.ru
Адрес: Республика Беларусь, г.Полоцк, ул. Гагарина 8, комн. 304.
4.1
Reset to Factory Defaults
For factory default settings set P0970 to 1 (with P0010 = 30). Where the
inverter is integrated with a non-Siemens motor, setting P0970 = 1 restores the
default parameter settings for the respective motor.
4.2
Additional Control Applications
The COMBIMASTER 411 and MICROMASTER 411 may also be controlled by
the following means:
Ø Digital inputs / Analogue inputs
Ø Serial Link via USS Protocol
Ø BOP/AOP Keypad Control
(Requires option module 6SE6401-1BL00-0AA0)
Ø Automated system via PROFIBUS connection (requires PROFIBUS
module 6SE6401-1PB00 - 0AA0).
4.2
Further information
For further information please refer to the Operating Instructions and Parameter
Lists on the CD delivered with the unit.
5
Dimensions
5.1
MICROMASTER 411 - Dimensions.
Case
Size
Height
B
135.6
(5.31)
C
170.6
(6.61)
Case
Size
GW1
B
42.9
(1.68)
C
43
(1.69)
Figure 5
Getting Started Guide – March 2002
A5E00157510A
Тел.: 8 (0214) 444395, 443688, 442155, (029) 6171554
Overall Dimensions
mm (inches)
Width
222
(8.74)
255
(10.04)
Gland Pitch
mm (inches)
GW2
GW3
82.9
175.0
(3.26)
(6.89)
83.0
203.4
(3.27)
(8.01)
Gland Dimensions
Weight
kg
(lbs)
Depth
154
4.9
(6.06)
(10.77)
177
7.4
(6.97)
(16.34)
Height
Sealing
mm
Surface
(inches)
(inches)
GH
27.6
(1.09)
(1.38)
38.3
(1.51)
(1.42)
Power Range
kW (hp)
0.37 – 1.5
(0.5 – 2.0)
2.2 – 3.0
(3.0 – 4.0)
Knock-out
Diameter
mm
mm
(inches)
GD1
GD2
35
26
(1.02)
36
26
(1.02)
15