Avoiding Electro-Magnetic Interference; Commissioning Combimaster 411/Micromaster 411; General Information - Siemens COMBIMASTER 411 Getting Started Manual

Hide thumbs Also See for COMBIMASTER 411:
Table of Contents

Advertisement

УП "Спецпривод-С". http://www.privod.by/. Email: info@privod.by, msv125@mail.ru
Адрес: Республика Беларусь, г.Полоцк, ул. Гагарина 8, комн. 304.
Notes:
Ø If a PTC resistor is
fitted, this should be
connected between 4
(+24 V) and 3 (DIN 3).
Ø Analog Input type:
voltage input 0 – 10V.
Ø 24 V power supply =
100 mA maximum.
Figure 6
Terminal
1
2
3
6/7
8/9
2

Avoiding Electro-Magnetic Interference

Good installation practices will ensure safe and trouble-free operation. For
further information see Operating Instructions.
3

Commissioning COMBIMASTER 411/MICROMASTER 411.

3.1

General Information

For default operation no additional equipment is required. However, for more
complex operation either the Basic Operator Panel (BOP), Advanced Operator
Panel (AOP) or Fieldbus options can be used. These are available as non-
standard options and must be ordered separately.
When delivered the inverter has a frequency setpoint range of between 0 Hz
and 50 Hz. Regardless of its initial position the Control Potentiometer must be
turned fully counter-clockwise before the inverter can start.
Warning
!
The inverter does not have a mains power switch and is
therefore live when the power supply is connected.
8
Getting Started Guide – March 2002
A5E00157510A
Тел.: 8 (0214) 444395, 443688, 442155, (029) 6171554
Control Circuit Input Terminals
Inputs
Digital Input 1 [DIN1]
Digital Input 2 [DIN2]
Digital Input 3 [DIN3]
Analog Input (-/+) [AIN]
Option: DIN4
Output Relay
8
9
RL1-B
RL1-C
1
2
3
4
5
DIN1 DIN2
DIN3
+24V
0V
Default operation
ON/OFF1
Reverse
Fault Acknowledge
0 – 10 V Analogue Input
Fault identification
6
7
AIN- AIN+