Check code
Location
Outdoor 7-segment display
Main
remote
detection
Check
Sub-code
controller
code
0 : IGBT circuit
IPDU
1 : Position
detection
circuit error
3 : Motor
lockup error
Note:
Although
letters 0 to
F appear at
locations
indicated
P22
P22
by " ",
please
ignore
them.
IPDU
P26
P26
IPDU
P29
P29
Indoor
unit
P31
of
Description
System status
Outdoor fan
All stop
IPDU error
All stop
All stop
IGBT (IPM)
All stop
short-circuit
protection error
Compressor
All stop
position
detection circuit
error
Other indoor
Stop of
error
corresponding
(group follower
unit
unit error)
104
126
Error detection
Check items (locations)
condition(s)
(Sub code: 0 )
Check fan motor.
Fan IPDU over current
Check for defect in
protection circuit
IPDU P.C. board.
Flow of current equal to or
greater than the specified
value is detected during
startup of the fan.
(Sub code: 1 )
Check fan motor.
Fan IPDU position detection
Check connection of fan
circuit
motor connector.
Position detection is not
Check for defect in
going on normally.
IPDU P.C. board.
(Sub code: 3 )
Check fan motor.
Gusty wind, an obstruction,
Check for defect in
or another external factor
IPDU P.C. board.
Speed estimation is not going
on normally.
Overcurrent is momentarily
Check connector
detected during startup of
connection and wiring on
compressor.
IPDU P.C. board.
Check for defect in
compressor (layer short-
circuit).
Check for defect in outdoor
P.C. board (IPDU).
Position detection is not
Check wiring and
going on normally.
connector connection.
Check for compressor
layer short-circuit.
Check for defect in
IPDU P.C. board.
There is error in other indoor
Check indoor P.C. board.
unit in group, resulting in
detection of E07 / L07 / L03 /
L08.

Hide quick links: