Maximum flue length and
number of bends
300 mm of straight flue
before any bends
Side direct, sided extended, side and back flueing
Side direct through the wall flueing for walls up to 385 mm thick. Flue can be extended if the wall
thickness is greater than 385 mm by using additional lengths of flue pipe, and the pipe can be
directed behind by using the flue transition extension and bend kit.
1. Direct flue kit
- ASPDFK
Back direct and back extended flueing
By changing the direction of the adaption flue position and connection, back direct and back direct
extended flueing is possible.
1. Adaption flue
- LSFKIT01
2. Wall terminal
- ESWTERM
Maximum flue length
Maximum number of bends = three
For every 90° bend, the overall length must be reduced by
1 m. For example, if an installation has three 90° bends, the
maximum flue length can be 5.5 m. The elbow component of
the Linear adaption flue kit (LSFKIT01) is not counted as a 90°
bend.
A minimum of 300 mm of straight flue is required before any
bends. This is required due to the heat produced from the initial
section of flue. The LSFKIT01 has the 300 mm minimum flue
length built in.
If using the direct flue (ASPDFK) and connecting to any bends,
a flue transition extension (LSFEXKIT01) must be connected to
achieve the minimum length.
1. Direct flue kit
- ASPDFK
2. Flue pipe
- ESPIPE900
1. Adaption flue
2. Flue pipe
3. Wall terminal
= 8.5 m
1. Direct flue kit
- ASPDFK
2. Flue transition - LSFEXTKIT01
3. 45° bends
- ESBEND
4. Flue pipe
- ESPIPE900
- LSFKIT01
- ESPIPE900
- ESWTERM
Linear flue installation guide 13541-A 01-20 | 7