AS302P Single Phase Smart Meter
____________________________________________________________________

17.4.2. Manual Entry Credit Top up

The Consumer can enter a UTRN either on the meter or on the PPMID.
The process for adding this code on the meter is described below:
The UTRN code is fixed to 20 characters long.
Only numeric characters are allowed (0...9). First 10 are shown on the first line of the display, the last 10 on the second
line.
Select Button
- A short button press at any character position will move the cursor forward (to the next character position).
- A short button press at the 20th character position will bring the cursor back to the 1st character position of the UTRN
code. This will help the user to re-enter any incorrect values before validating it.
- A long button press at the 20th character position indicates that the code entry is complete and that the code can now be
validated by the meter.
Next Button
- Enables user to change the UTRN character by increasing the value from 0 to 9 and then wrapping around back to 0.
The character currently selected will flash until the "SELECT" button is pressed. Once a code has been selected the
cursor will move to the right immediately (to enable the next character selection).
If the UTRN code validation is successful the meter shows the following message: TopUp Accepted.
If the UTRN code validation is unsuccessful, the meter shows the following message: TopUp Rejected. A short press of
the "SELECT" button will show: "Retry?" - first line, "Yes/No" - second line. In this case:
- "SELECT" button: allows the user to select an option.
- "NEXT" button: allows the user to navigate between options. The selected option will flash.
If "Yes" is selected then UTRN entry menu is shown again.
If "No" is selected then the meter returns to parent menu.
After 10 successive invalid entries, the e-meter removes the UTRN code entry offer for 30 minutes [if this is active then the
e-meter shows: "Restricted" - first line, "for xxx sec"- second line]

17.4.3. Allocation of Credit Top up

Before Credit is added to the Meter Balance appropriate charges need to be deducted.
Payment Based Debt (subject to Debt Recovery Cap – See Section 17.7.2)
Accumulated Debt (See Section 17.7.3)
Emergency Credit Used (See Section 17.7.5)
See 34.10 for the logical operation of the TopUp Allocation.